Search Proceedings
Who we are
UNCERTAINTY ANALYSIS AND LONG-TERM STABILITY INVESTIGATION OF THE GERMAN PRIMARY HIGH-PRESSURE NATURAL GAS TEST FACILITY pigsar
Wolfram Bremser, Werner Hässelbarth, Uwe Hirlehei, Hans-Jürgen Hotze, Bodo Mickan, Rainer Kramer, Dietrich Dopheide
-
Abstract:The high-pressure gas flow meter test facility pigsar operated by Ruhrgas AG serves for testing and calibration of turbine-wheel and ultrasonic meters for natural gas in the pressure range between 14 and 50 bar and flow rates ranging from 8 to 6500 m³ / h. Pigsar is the national standard of high-pressure natural gas flow under supervision of the German national metrological institute PTB. It represents and disseminates the unified German-Dutch reference value for the unit of volume for high-pressure natural gas. The uncertainty analysis of the test facility presented here was one of the main pre-requisites for the creation of the harmonised reference value.
-
Keywords:
-
Download:
-
DOI:_unreg_tc9-2003.002
Event details:
-
IMEKO TC:TC9
-
Event name:FLOMEKO 2003
-
Title:11th Conference on Flow Measurement
-
Place:Groningen, NETHERLANDS
-
Time:12 May 2003 - 14 May 2003