THE TRIANGULATION METHOD OF CONTACT-LESS DIMENSION MEASUREMENT USING AN AREA CMOS IMAGING SENSOR

Jan Fischer, Tomáš Radil, Jan Šedivý
  • Abstract:
    The so-called triangulation method of contact-less dimension measurement determines the measured object’s dimension from its shadow projected on an imaging sensor without lens. A point light source is used to illuminate the measured object. The so far used linear CCD sensors introduced a considerable uncertainty to the measurement. Application of area CMOS imaging sensors improves the measurement uncertainty and enables to use some new measurement methods. A special CMOS measuring camera was designed for this purpose.
  • Keywords:
  • DOI:
    _unreg_tc4-2004.103

Event details:

  • IMEKO TC:
    TC4
  • Event name:
    TC4 Symposium 2004
  • Title:
    XIII IMEKO TC4 International Symposium on Measurements for Research and Industrial Applications (together with IXth International Workshop on ADC Modeling and Testing, IWADC)
  • Place:
    Athens, GREECE
  • Time:
    29 September 2004 - 01 October 2004