Skip to main content

The Interesting Effect of Non-uniform Sampling

Adam Derkowski
  • Abstract:
    It is well known, that the proper ratio between frequencies of testing signal and sampling signal is required, during a dynamic testing of waveform recorders or analog-to-digital converters. A lot of testing methods suggest applying a coherent sampling, which assures a uniform distribution of samples between 0 and 2π. The paper presents results obtained with Matlab numerical simulations showing influence of the sampling strategy on establishing performances of analog-to-digital converters. It was shown, that the results of tested conversions are different if a non-coherent sampling is applied. A proposal of sampling is presented in case of using a sinewave as an exciting, input signal.
  • Keywords:
  • DOI:
    _unreg_tc4-2005.113

Event details:

  • IMEKO TC:
    TC4
  • Event name:
    TC4 Workshop 2005
  • Title:

    10th IMEKO TC4 International Workshop on ADC Modelling and Testing - IWADC (together with XIVth IMEKO TC4 International Symposium on New Technologies in Measurement and Instrumentation)

  • Place:
    Gdynia/Jurata, POLAND
  • Time:
    12 September 2005 - 15 September 2005