Skip to main content

Study on the Tests of Large-Bore Flow Measurement Using FJPE-Type Gauging Pipes

Zhou Guo-xiang, Wang Jing-an, Li Chunhui
  • Abstract:
    Several tests using FJPE-type gauging pipes for improving the accuracy of large-bore flow measurement have been described herein. The measuring test of non-fully developed pipe flow, which is formed in the elbow, is discussed especially, including research processes, part of data-processing result, and flow velocity profiles at the cross-section of pipes. The initial results indicate that, measurement of large-bore flow by varied-bore pipe is of significant flow-rectifying effects, which reduces the length-requirements of straight tubes as well. The gauge constant fluctuated little within the larger Reynolds number range. This kind of research provides a new method for large-bore flow measurement.
  • Keywords:
    metrology, large-bore flow, FJPE-type pipe, varied-bore pipe, non-fully developed pipe flow
  • DOI:
    _unreg_tc9-2010.056

Event details:

  • IMEKO TC:
    TC9
  • Event name:
    FLOMEKO 2010
  • Title:

    15th Conference on Flow Measurement

  • Place:
    Taipei, CHINESE TAIPEI (economy)
  • Time:
    12 October 2010 - 14 October 2010