Stator Winding Fault Diagnosis in Permanent Magnet Synchronous Generators Based on Short-Circuited Turns Identification Using Extended Kalman Filter
B. Aubert, J. Regnier, S. Caux, D. Alejo
-
Abstract:This paper deals with an Extended Kalman Filter (EKF) based fault detection for inter-turn shortcircuit in Permanent Magnet Synchronous Generators (PMSG). A specific faulty model in d-q frame is developed to estimate the number of short-circuited turns which are used to a fault indicator setting up. Simulation results demonstrate the sensitivity and the robustness of the chosen indicator against various operation points on an electrical network.
-