Search Proceedings
Who we are
SHAPE CORRECTION ALGORITHM BY COMPARING SHAPE SILHOUETTE-LINES WITH A SINOGRAM
Trung Vuong Pham, Yutaka Ohtake, Yukie Nagai, Hiromasa Suzuki
-
Abstract:In industrial X-ray CT application, there is an increasing demand for achieving accurate surface reconstruction of measured objects for dimensional inspection of mechanical parts since the performance of industrial X-ray CT scanners is considerably improved. In this paper, we propose a novel method that reuses X-ray projection images, or a sinogram, to improve the accuracy of the reconstructed surface mesh by correcting the CT values, which is done by fitting silhouette- lines of the mesh to the sinogram. The sinogram is conventionally used only for obtaining a CT volume data, or a tomogram. Since it has become capable to extract the silhouette-lines correctly regardless of beam hardening etc., reusing the sinogram has the potential application for improving the accuracy of the reconstructed mesh.
-
Keywords:X-ray computed tomography, shape silhouette-lines, shape correction
-
Download:
-
DOI:_unreg_tc14-2014.40
Event details:
-
IMEKO TC:TC14
-
Event name:TC14 LMPMI Symposium 2014
-
Title:
11th Symposium on Laser Metrology for Precision Measurement and Inspection in Industry
-
Place:Tsukuba, JAPAN
-
Time:03 September 2014 - 05 September 2014