Skip to main content

Primary standard for liquid hydrocarbon at low flow rates using light oil, kerosene and industrial gasoline

K.-H. Cheong, R. Doihara, N. Furuichi, T. Shimada, Y. Terao
  • Abstract:
    Motivated by the need to establish a measurement traceability in engine fuel consumption for the industry (automobile, shipping and aviation) as well as in the household fuel metering and bio-fuel production (bio-fuel blending), NMIJ developed a primary standard for low liquid hydrocarbon flow rates that works on three common types of liquid fuels, namely light oil (diesel), kerosene and industrial gasoline (flash point over 40 °C). To achieve a high calibration accuracy below 0.1 % which is needed by the industry, this primary standard adopted the gravimetric method performing static weighing with flying-start-and-finish as the calibration method. To cater to a wide flow range from 0.02 L/h to 100 L/h, the calibration facility operates on two gravimetric systems, one using a compactly designed conical rotating double-wing diverter for 1 L/h to 100 L/h and another using a pair of high-speed switching valves as a diverter for 0.02 L/h to 1 L/h. Features of each gravimetric system and its performance are highlighted in the paper. For validation of the calibration capability of the primary standard, uncertainty analysis as well as intra-comparisons with other facilities at NMIJ are also reported.
  • Keywords:
  • DOI:
    _unreg_tc9-2019.077

Event details:

  • IMEKO TC:
    TC9
  • Event name:
    FLOMEKO 2019
  • Title:

    18th International Flow Measurement Conference 2019

  • Place:
    Lisbon, PORTUGAL
  • Time:
    26 June 2019 - 28 June 2019