Search Proceedings
Who we are
PRECISION VECTOR-DIFFERENCE TRANSFORMER WITH HIGH COMMON-MODE REJECTION
F. Cabiati, U. Pogliano, G. C. Bosco
-
Abstract:The problem of obtaining the difference of two AC voltages represented by vectors with arbitrary amplitude and phase at accuracy levels unattainable with electronic amplifiers is addressed. A solution consisting in a precision complex transformer is presented, together with a mathematical model and some preliminary studies of more general interest. A shielded prototype has performed accuracy levels below 1 × 10-6 from 30 Hz to 12 kHz and a common-mode rejection ratio exceeding 140 dB from 800 Hz to 40 KHz.
-
Keywords:AC difference, common-mode rejection, precision transformer
-
Download:
-
DOI:_unreg_tc4-2001.097
Event details:
-
IMEKO TC:TC4
-
Event name:TC4 Symposium 2001
-
Title:
11th IMEKO TC4 Symposium on Trends in Electrical Measurements and Instrumentation (together with 6th IMEKO TC4 Workshop on ADC Modelling and Testing)
-
Place:Lisbon, PORTUGAL
-
Time:13 September 2001 - 14 September 2001