Skip to main content

Performance evaluation test of Coriolis flow meters for hydrogen metering at high pressure

T. Morioka
  • Abstract:
    This paper describes the results of performance evaluation of Coriolis flow meters from various manufacturers in high-pressure hydrogen actual flow using a calibration system with critical flow Venturi nozzles as a reference. The calibration system consisting of five nozzles was developed to calibrate the flowmeters by high-pressure, high-flow-rate hydrogen gas. The performance evaluation test of the Coriolis flowmeters wasconducted at maximum pressure of 70 MPa, gas temperature of 0 °C and -40 °C, and flow rate range from 0.5 kg/min to 3.0 kg/min. It was confirmed that the instrumental error of most of the DUTs tested in this paper was within ± 2.0 %, although the instrumental error tended to be slightly larger at -40 °C in the small flow rate range.
  • Keywords:
    Hydrogen; Coriolis Flowmeter; High Pressure; Fuel Cell Vehicle; Critical Flow Venturi Nozzle
  • DOI:
    tc9-2022.162

Event details:

  • IMEKO TC:
    TC9
  • Event name:
    FLOMEKO 2022
  • Title:

    19th International Flow Measurement Conference 2022

  • Place:
    Chongqing, CHINA
  • Time: