  • Abstract:
    A new non-destructive method was developed for the detection of refrigerant leakage at an evaporator’s inflow. Nitrogen and oxygen gas were blown through the evaporator in successive time intervals. A gas analyser was applied at the outflow of the evaporator and the oxygen concentration measured. It was possible to detect any leakage by investigating the oxygen concentration-time history diagram.
  • Keywords:
    leakage detection, refrigeration, plate evaporator
  • DOI:
    _unreg_wc-2006.TC9-011

Event details:

  • IMEKO TC:
  • Event name:
    XVIII IMEKO World Congress
  • Title:

    Metrology for a Sustainable Development

  • Place:
    Rio de Janeiro, BRAZIL
  • Time:
    17 September 2006 - 22 September 2006