Search Proceedings
Who we are
Measurement of Frequency Dependences of Low-Value Four-Terminal Resistance Standards
Jaroslav Bohacek
-
Abstract:A 10 Ω quadrifilar resistor with calculable frequency dependence served as a reference in measurement of frequency dependences of resistance standards ranging from 1 Ω to 0.01 Ω in a frequency range up to 10 kHz. In this measurement, a step-down method based on successive 10:1 comparisons of the standards by means of a transformer bridge was used. Ratio arms of this bridge being formed by an eight-decade, two-stage inductive voltage divider, a small variable voltage injected into one connecting lead of the ratio winding of the divider serves for quadrature balancing.
-
Keywords:current shunt, calculable resistor, transformer bridge
-
Download:
-
DOI:_unreg_tc4-2013.009
Event details:
-
IMEKO TC:TC4
-
Event name:TC4 Symposium 2013
-
Title:19th IMEKO TC4 Symposium Measurements of Electrical Quantities (together with 17th TC4 IWADC Workshop on ADC and DAC Modelling and Testing)
-
Place:Barcelona, SPAIN
-
Time:18 July 2013 - 19 July 2013