Abstract:A new torque calibration machine with a torque capacity of 5 kN·m has been installed in Force and Pressure Laboratory of GUM. This reference type machine generates torques in vertical axis in a range from 10 N·m to 5 kN·m with an expanded relative measurement uncertainty of 0,04 % (k = 2). Performance of the machine has been evaluated via comparison between GUM and PTB. Results of comparison measurement are presented.
-