INTER-LABORATORY COMPARISON OF REFERENCE TORQUE WRENCH CALIBRATION BETWEEN NMIJ AND PTB IN THE RANGE OF FROM 200 N·m TO 2 kN·m

Koji Ogushi, Atsuhiro Nishino, Koji Maeda, Kazunaga Ueda, Andreas Brüge, Dirk Röske
  • Abstract:
    Inter-laboratory comparison of reference torque wrench calibration was conducted between NMIJ and PTB using a torque transducer in the form of a torque wrench, "TTS/3kNm", as a transfer device. Although the rated capacity of the transducer is 3 kN·m, the calibration range of from 200 N·m to 2 kN·m was selected. Each loading time schedule used in daily calibration was also adopted in this comparison. Calibration results obtained by both laboratories coincided with the range of uncertainties.
  • Keywords:
    torque, torque wrench, reference torque wrench, comparison, square drive
  • DOI:
    _unreg_wc-2012.TC3-O32

Event details:

  • IMEKO TC:
  • Event name:
    XX IMEKO World Congress
  • Title:

    Metrology for Green Growth

  • Place:
    Busan, REPUBLIC of KOREA
  • Time:
    09 September 2012 - 12 September 2012