Search Proceedings
Who we are
INMETRO ZINC FIXED-POINT OPEN CELL
Slavolhub G. Petkovic, Paulo R.F. Santos, Antônio C. Baratto, Hamilton D. Vieira ,Renato N. Teixeira, Klaus N. Quelhas
-
Abstract:A zinc fixed-point open cell (419.527 °C) was manufactured by the Thermal Metrology Division of Inmetro for the realisation of the International Temperature Scale of 1990 (ITS-90). This paper presents the fixed-point cell design, fabrication method, results of the cell evaluation and the estimated uncertainty assigned to the temperature of the cell.
-
Keywords:Zinc point, fixed-point, temperature
-
Download:
-
DOI:_unreg_wc-2006.TC12-003
Event details:
-
IMEKO TC:
-
Event name:XVIII IMEKO World Congress
-
Title:
Metrology for a Sustainable Development
-
Place:Rio de Janeiro, BRAZIL
-
Time:17 September 2006 - 22 September 2006