INMETRO’S PRIMARY AC-DC CURRENT TRANSFER STANDARD BASED ON PMJTCS
R. Afonso, M. Klonz, R. M. Souza, R. P. Landim
-
Abstract:This paper describes the new primary standard for the ac-dc current transfer at Inmetro, based on PMJTCs and the new shunts manufactured by Fluke for rated currents from 10 mA up to 20 A. The build-up of the ac-dc current scale is described together with the uncertainty budgets which result in final uncertainties at 5 A of 6 μA/A to 12 μA/A in the frequency range from 10 Hz to 100 kHz. These are small compared to international standards.
-
Keywords:ac-dc difference, PMJTC, comparison
-
Download:
-
DOI:_unreg_tc4-2011.049
Event details:
-
IMEKO TC:TC4
-
Event name:TC4 Symposium 2011
-
Title:
XVIIIth IMEKO TC4 International Symposium on Measurement of Electrical Quantities (part of Metrologia2011, together with IX International Congress on Electrical Metrology - IX SEMETRO)
-
Place:Natal, BRAZIL
-
Time:27 September 2011 - 30 September 2011