HIGH RESISTANCE COMPARISON AMONG KRISS, VNIIM AND NIM

K. M. Yu, J. C. Ryu, Y. P. Semenov, B. Litvinov, S. Haiming
  • Abstract:
    In a high resistance comparison among KRISS, VNIIM and NIM, the relative resistance values of measurement results agreed well within 2 ppm in 10 megohm and 5 ppm in 1 gigohm. Also, relative combined standard uncertainties of the three institutes for the values is not beyond 4 ppm in 10 megohm and 8 ppm in 1 gigohm.
  • Keywords:
    high resistance comparison, 10 megohm and 1 gigohm, adapted Wheatstone bridge, binary voltage divider bridge
  • DOI:
    _unreg_wc-2000.230

Event details:

  • IMEKO TC:
  • Event name:
    XVI IMEKO World Congress
  • Title:

    Measurement - Supports Science - Improves Technology - Protects Environment ... and Provides Employment - Now and in the Future

  • Place:
    Vienna, AUSTRIA
  • Time:
    25 September 2000 - 28 September 2000