Skip to main content

EXPERIMENTAL STUDY OF THE FACTORS EFFECT ON THE S TYPE PITOT TUBE COEFFICIENT

Nguyen Doan Trang, Woong Kang, Jae Sig Shim, Hee Soo Jang, Seung Nam Park, Yong Moon Choi
  • Abstract:
    For the measurement of velocity of gas streams in ducts, the S pitot tube is one of the most widely used velocity measurement devices. Factors as Reynolds number and misalignment can be additional error sources for the S pitot coefficient. The variation of S pitot coefficient is observed on five different manufactures of S pitot through the airs peed standard system. The results of these experiments indicate that the coefficient curve of S pitot tube is fluctuated at small velocities around 0.2 % up to 0.7 %. The coefficient value of S pitot tube has a band from 2 % to 4 %
  • Keywords:
    S pitot tube, misalignment, yaw and pitch angle, coefficient
  • DOI:
    _unreg_wc-2012.TC9-O5

Event details:

  • IMEKO TC:
  • Event name:
    XX IMEKO World Congress
  • Title:

    Metrology for Green Growth

  • Place:
    Busan, REPUBLIC of KOREA
  • Time:
    09 September 2012 - 12 September 2012