  • Abstract:
    This study analyzes an end-shorting effect on electro-magnetic flowmeters with short distance between connecting flanges around about 5 D. The Bevir's formulation is extended to conducting pipe wall. Through the evaluation of the Green function satisfying the corresponding boundary conditions, presice formula is obtained.