Skip to main content

Design Approach for a Stand Alone Merging Unit

Giuliano Cipolletta, Antonio Delle Femine, Daniele Gallo, Carmine Landi, Mario Luiso
  • Abstract:
    In order to enhance levels of security and reliability of power systems, allowing for advanced remote diagnostics, Merging Units (MUs) play a key role. Some of the benefits are a more efficient transmission of electricity and a better integration with renewable energy systems. In this paper an implementation of a Stand Alone Merging Unit (SAMU), compliant with the IEC 61850-9-2 standard and based on a low cost ARM microcontroller, is described. It acquires two signals, one voltage and one current, and it sends the samples over the Ethernet connection. A high-resolution analog to digital converter (ADC), synchronized to the Universal Time coordinated (UTC) through a Global Positioning System (GPS) disciplined oscillator, is used. The results of the characterization of the ADC are presented.
  • Keywords:
    Power System Measurement, Power System Diagnostics, Stand Alone Merging Unit, Time Synchro- nization, Analog To Digital Converter
  • DOI:
    _unreg_tc10-2019.016

Event details:

  • IMEKO TC:
    TC10
  • Event name:
    TC10 Conference 2019
  • Title:

    16th IMEKO TC10 Conference "Testing, Diagnostics & Inspection as a comprehensive value chain for Quality & Safety"

  • Place:
    Berlin, GERMANY
  • Time:
    03 September 2019 - 04 September 2019