Skip to main content

ANOTHER APPROACH ANALYZING THE CROSSTALK MATRIX FOR A PRECISE FORCE-TORQUE TRANSDUCER

Koji Ogushi, Sebastian Baumgarten, Dirk Röske
  • Abstract:
    A new multi-component facility for force and torque, which can simultaneously realize precise axial force (Fz) and torsional moment (torque, Mz), is being developed in PTB. Moreover, precise two-axis measuring devices (force-torque transducers) as transfer standards must be also developed for the establishment of the measurement traceability of screw testing machines. Authors have calibrated a new-developed force-torque transducer in each direction of force and torque, separately. The crosstalk matrixes have been obtained by ordinal way, where the normal square-inverse matrix (2 by 2) was used. In this paper, authors tried to obtain the crosstalk matrix by means of another approach, pseudo-inverse matrix, where the data was used as many as possible (2 by 18 or 2 by 26), and the useful crosstalk matrix could be determined in one value.
  • Keywords:
    multi-component measurement, force, torque, screw testing machine, pseudo-inverse matrix
  • DOI:
    _unreg_wc-2015.068

Event details:

  • IMEKO TC:
  • Event name:
    XXI IMEKO World Congress
  • Title:

    Measurement in Research and Industry

  • Place:
    Prague, CZECH REPUBLIC
  • Time:
    30 August 2015 - 04 September 2015