Search Proceedings
Who we are
AN AUTOMATIC SYSTEM FOR CURRENT TRANSFORMER TEST SET CALIBRATIONS
Hüseyin Çaycı
-
Abstract:A practical method with high accuracy in generation and application of error values for calibration of current transformer test sets is described. A PC-controlled three-phase power source with a standard wattmeter is used for generating the nominal and error test currents while an electronically compensated current comparator is used to provide summation and subtraction of them, precisely. With this method, any ratio error and phase displacement value could be generated automatically and nominal and test currents could be grounded on the test set safely. Because of its high accurate ratio and phase error generating capability, any type of test set regardless of its operating principles could be calibrated.
-
Keywords:
-
Download:
-
DOI:_unreg_tc4-2010.125
Event details:
-
IMEKO TC:TC4
-
Event name:Instrumentation for the Information and Communication Technology Era
-
Title:XVIIth IMEKO TC4 Symposium & 15th International Workshop on ADC Modelling and Testing (together with 3rd IMEKO TC19 Symposium)
-
Place:Kosice, SLOVAKIA
-
Time:08 September 2010 - 10 September 2010