Skip to main content

ACCURACY EVALUATION IN THIAMIN QUANTIFICATION IN FOOD MATRICES

Cristina Flores, M. Graça Dias, Mariana Santos
  • Abstract:
    The performance evaluation of an RP-HPLC method to determine thiamine using different food matrices and reference materials, showed the method suitability to its purpose and to be submitted to accreditation. Intermediate precision evaluate through the relative standard deviation (RSD%) was under 8% for all food matrices tested an all the z-scores obtained for the reference materials were < 1.5.The estimated expanded measurement uncertainty was 13%.
  • Keywords:
    thiamin, accuracy, foods, HPLC
  • DOI:
    _unreg_wc-2015.447

Event details:

  • IMEKO TC:
  • Event name:
    XXI IMEKO World Congress
  • Title:

    Measurement in Research and Industry

  • Place:
    Prague, CZECH REPUBLIC
  • Time:
    30 August 2015 - 04 September 2015