Skip to main content

A PIV EXAMINATION ON THE PERFORMANCE OF ULTRASONIC HEAT METER RELATED TO INSTALLATION

Wang Sun, Luhai Wang, Jiming Yang, Yujian Zhu
  • Abstract:
    An experimental investigation was carried out on the performance of an ultrasonic heat meter with interference of non-uniformity from the upstream installation of a ball valve, which it is partly opened. It was found that the existence of the ball valve may under-report the flow, especially when the flow rate is low. From the measured PIV results, it can be found that the velocity distribution is obviously non-uniform inside the meter, and the change is remarkable when the inlet is added with a ball valve. The time resolved PIV results also demonstrate that the flow field becomes unsteady when slow down the flow rate, which might be responsible for the measurement deviation.
  • Keywords:
    PIV, ultrasonic heat meter, ball valve
  • DOI:
    _unreg_tc9-2013.053

Event details:

  • IMEKO TC:
    TC9
  • Event name:
    FLOMEKO 2013
  • Title:

    16th International Flow Measurement Conference

  • Place:
    Paris, FRANCE
  • Time:
    24 September 2013 - 26 September 2013