Skip to main content

QUANTIFYING IMPACTS ON THE MEASUREMENT UNCERTAINTY IN FLOW CALIBRATION ARISING FROM DYNAMIC FLOW EFFECTS

Rainer Engel, Hans-Joachim Baade
  • Abstract:
    Traceability of the measurement units in fluid flow metering, as the state-of-the-art approach, is practiced as a so-called element-by-element method which relies upon the idealistic assumption that the measurement process in a flow calibration facility can be run under exact steady-state conditions, i.e. absolutely no fluctuations of the flow quantities are assumed to occur during the flow measurement process. Practical experiences, combined with a model-based analytical view of the measurement process in a flow standard, have revealed that dynamic impacts on the measurement uncertainty due to flow rate fluctuations have to be taken into account, in addition to the steady-state traceability chain.
  • Keywords:
    liquid flow calibration, fluctuation of process parameters, measurement uncertainty analysis, traceability in fluid flow, element-by-element chain of traceability, dynamic system behavior
  • DOI:
    _unreg_tc9-2013.014

Event details:

  • IMEKO TC:
    TC9
  • Event name:
    FLOMEKO 2013
  • Title:

    16th International Flow Measurement Conference

  • Place:
    Paris, FRANCE
  • Time:
    24 September 2013 - 26 September 2013