Search Proceedings
Who we are
INTER-LABORATORY COMPARISONS BETWEEN NMIJ AND ACCREDITED LABORATORIES FOR WATER FLOW IN JAPAN
N Furuichi, Kar-Hooi Cheong, Y Terao
-
Abstract:Inter-laboratory comparisons between NIMJ and four JCSS accredited laboratories in Japan for water flow are carried out for wide flowrate range from 0.005 m3/h to 5000 m3/h using five type transfer flowmeters. The deviations of test results between NMIJ and the accredited labs are within approximately 0.1% and the averages of these deviations for each accredited labs are within 0.025%. These result indicate a high capability of the calibration facilities in the accredited labs. To investgate the reason of the deviations in the comparisons, influences of temperature, density and measurement time are observed.
-
Keywords:intercomparisons, water flow, tempertature, density, measurement time
-
Download:
-
DOI:_unreg_tc9-2013.057
Event details:
-
IMEKO TC:TC9
-
Event name:FLOMEKO 2013
-
Title:
16th International Flow Measurement Conference
-
Place:Paris, FRANCE
-
Time:24 September 2013 - 26 September 2013