Search Proceedings
Who we are
ESTIMATION OF POWER-LINE FREQUENCY WITH LOW UNCERTAINTY FOR HIGH HARMONIC DISTORTION OF SIGNALS
Jan Blaska, Milos Sedlacek
-
Abstract:The paper compares four methods (zerocrossing with pre-filtration, integrated zero crossing, windowed and interpolated FFT, and dynamic parameter estimation with pre-filtration) of instantaneous power-line frequency estimation from the point-of-view of their sensitivity to higher-order harmonic content and to the additive noise and from the point-of-view of their response time. Comparison is based on computer simulations.
-
Keywords:power-line frequency measurement, interpolated FFT, zero-crossing method, integrated zero-crossing method
-
Download:
-
DOI:_unreg_tc4-2001.018
Event details:
-
IMEKO TC:TC4
-
Event name:TC4 Symposium 2001
-
Title:
11th IMEKO TC4 Symposium on Trends in Electrical Measurements and Instrumentation (together with 6th IMEKO TC4 Workshop on ADC Modelling and Testing)
-
Place:Lisbon, PORTUGAL
-
Time:13 September 2001 - 14 September 2001