Skip to main content

ACCURACY ENHANCEMENT OF A COMBINED V/Z CLAMP-ON ULTRASONIC FLOW

Sejong Chun, Byung-Ro Yoon, Woong Kang, Hyu-Sang Kwon
  • Abstract:
    Ultrasonic flow metering with clamp-on type transducers is a promising method when portability in flow metering is necessary. Nevertheless, the clamp-on ultrasonic flow meter has low measurement accuracy as flow speed in the pipe decreases. If the two types of clamp-on ultrasonic flow paths, namely, Z-shaped and V-shaped ultrasonic paths, are combined, measurement accuracy can be increased because the metering output becomes robust. In the present study, the measurement accuracy of the combined clamp-on ultrasonic flow meter was within ±2 % at 50 m3/h, which was smaller than those of the Z-shaped and the V-shaped clamp-on ultrasonic flow meters at the same flow rate. This can provide an advantage for water resource management because a general guideline for the water resource management is less than ±2 %.
  • Keywords:
    clamp-on ultrasonic flow meter, V-shaped, Z-shaped
  • DOI:
    _unreg_tc9-2013.083

Event details:

  • IMEKO TC:
    TC9
  • Event name:
    FLOMEKO 2013
  • Title:

    16th International Flow Measurement Conference

  • Place:
    Paris, FRANCE
  • Time:
    24 September 2013 - 26 September 2013